ANSI Bushing

  • 15KV /125A ANSI Bushing (Shank‑type bushing connector)for Pole‑Mount Distribution Transformers
15KV /125A ANSI Bushing (Shank‑type bushing connector)for Pole‑Mount Distribution Transformers

15KV /125A ANSI Bushing (Shank‑type bushing connector)for Pole‑Mount Distribution Transformers

15‑34KV /125A ANSI Bushing (Shank‑type bushing connector)

Overview

A 15‑34 kV /125 A ANSI shank‑type bushing connector is a standardized medium‑voltage insulating component designed for ANSI‑compliant oil‑immersed distribution transformers. The term shank‑type bushing connector refers to the through‑rod terminal structure: a solid metal shank runs axially through the bushing core, forming the conductive connection point for external overhead lines or busbar terminals. Differentiated from shovel‑face opening variants and cable‑through bushings, this shank‑connector design features threaded top terminals (M10*1.5), offering compact, reliable mechanical connection for low‑current ANSI distribution transformers.

Rated for system voltages covering 15 kV,18 kV,25 kV and 34 kV with a continuous current rating of 125 A, this bushing acts as the critical barrier that enables energized internal transformer conductors to pass safely through the grounded metal transformer tank. It delivers dual performance: robust dielectric insulation to prevent high‑voltage leakage, plus solid mechanical support for the shank‑type connector assembly.

Medium‑voltage distribution equipment following North‑American ANSI standards faces multiple operating stresses: power‑frequency voltage, lightning impulse surges, short‑circuit current shocks, transformer‑induced vibration, as well as outdoor environmental hazards including coastal salt fog, industrial dust, and wide temperature fluctuations. Under‑specified or low‑quality bushings are one of the leading root causes of unplanned transformer outages, partial discharge faults, and premature insulation aging. The 15‑34 kV /125 A shank‑type ANSI bushing is purpose‑built to withstand these harsh service conditions, complying with ANSI dimensional and electrical requirements for pole‑mounted and pad‑mounted distribution transformers.

This bushing series is widely used for small‑capacity utility distribution transformers, industrial auxiliary transformers, and renewable‑energy‑related transformer projects. Matched accessories include aluminum mounting clamp and terminal protective cover, supporting both new transformer manufacturing and field spare‑part replacement work.

What is Shank‑type Bushing Connector for ANSI Transformer Bushing

The shank‑type bushing connector describes the through‑rod conductive terminal structure. A solid metal shank penetrates the full inner bore of the insulator body, with externally threaded terminals at the top for bolted connection to external conductors. Unlike shovel‑face opening bushings which adopt angled flat mounting interface, this model uses compact M10×1.5 threaded shank terminals for wiring connection.

Complete assembly of this ANSI bushing includes multi‑shed insulating housing, inner shank‑type connector, aluminum mounting clamp, tank‑sealing components, and detachable protective cover. The tank opening dimension follows standard ANSI specifications, allowing direct installation onto oil‑filled transformer tank walls.

Key electrical parameters cover voltage classes 15 kV,18 kV,25 kV,34 kV and fixed 125 A continuous current rating. Every unit must satisfy ANSI‑defined test requirements: power‑frequency withstand voltage, lightning impulse withstand level, short‑time short‑circuit current resistance, and sufficient creepage distance for polluted outdoor operating environments.

Core Advantages of 15‑34KV /125A ANSI Bushing (Shank‑type bushing connector)

  1. Standard ANSI‑compliant shank‑connector geometryThe M10×1.5 threaded shank‑type bushing connector follows ANSI dimensional standards. It pairs perfectly with standard aluminum clamp and protective‑cover accessories, simplifying replacement for existing ANSI‑designed pole‑mount and pad‑mount transformers.
  2. Optimized anti‑pollution multi‑shed insulationGraduated multi‑shed profile provides adequate creepage and arcing distance for different voltage grades. It maintains stable insulation performance under coastal salt‑fog corrosion, industrial dust accumulation and high‑humidity outdoor environments. Different shed quantities are configured for each voltage class to meet site pollution‑level requirements.
  3. Compact and reliable shank‑through conductionIntegral shank‑type connector structure delivers stable 125 A continuous current‑carrying capacity. Optimized thermal design restricts temperature rise under full‑load operation and slows insulation thermal ageing. Threaded top terminal offers convenient, repeatable bolt‑on connection for overhead conductors.
  4. Simple installation and maintenance workflowStandard Φ140 tank opening matches mainstream ANSI transformer tank cut‑outs. The matched protective cover shields threaded shank‑connector terminals against bird contact, UV degradation and atmospheric contamination. No complex internal oil‑filling steps are needed during field mounting.
  5. Broad application adaptabilityCovers four mainstream medium‑voltage ANSI voltage classes:15 kV,18 kV,25 kV,34 kV at 125 A nominal current. It fits small‑capacity distribution transformers for utility grid, industrial sites and renewable‑energy facilities, supporting both OEM manufacturing and retrofit maintenance projects.

Technical Specification Table: 15‑34KV /125A ANSI Bushing (Shank‑type bushing connector)

ModelRated Voltage(kV)Rated Current(A)H (mm)h2 (mm)h3 (mm)d1 (mm)d2 (mm)d5 (mm)Tank Opening Φd0 (mm)Arcing Distance(mm)Creepage Distance(mm)Number of Sheds
ANSI‑15/12515125380.5184.155310167.8247.5Φ14071.2279.464
ANSI‑15‑1251512527357.134.592.9654.8547.5Φ14057.23306
ANSI‑18/12518125437.5184.453100.8467.5647.5Φ14071.2450.857
ANSI‑25/12525125490184.45398.5567.8247.5Φ14071.2523.758
ANSI‑25‑12525125495184531016847.5Φ14071.277510
ANSI‑34/12534125567.5184.1553106.6867.8247.5Φ14071.2774.9211

Note: All dimensions are given in millimeters. Custom dimensions are available on request, including adjustable h3 height to satisfy special transformer tank mechanical layouts.

Typical Application Scenarios

  • ANSI‑standard pole‑mounted oil‑immersed distribution transformers for public utility power grids
  • Small‑capacity pad‑mount transformers for residential and commercial power supply
  • Auxiliary transformers for North‑American‑style industrial installations
  • Transformer retrofit and spare‑part replacement projects for existing ANSI‑type equipment
  • Step‑up transformers for wind‑power and solar‑power renewable‑energy projects adopting ANSI specifications

In every application, the shank‑type bushing connector forms the critical electrical transition point between transformer internal windings and external overhead power lines. Engineers must select proper model by matching voltage rating, current capacity, creepage distance and tank‑opening dimension according to site altitude and environmental pollution grade.

Key Selection Criteria

  1. Voltage and current rating: Match rated voltage (15 kV /18 kV /25 kV /34 kV) and 125 A nominal current against transformer nameplate parameters.
  2. Creepage distance & shed quantity: Select sufficient creepage distance corresponding to site pollution level; coastal salt‑polluted locations require higher creepage values.
  3. Transformer tank opening: Confirm tank cut‑out dimension and mounting hole layout for compatibility with aluminum clamp assembly.
  4. Altitude derating: For installation sites over 1000 m altitude, perform insulation derating calculation following ANSI technical guidelines.
  5. Connector mechanical compatibility: Verify M10×1.5 threaded shank‑type bushing connector dimension, matching external wiring hardware and protective‑cover fit.

Installation & Operational Recommendations

  • Inspect insulator sheds for cracks, scratches or mechanical damage before installation. Surface defects may trigger partial‑discharge risks during energized service.
  • Fasten aluminum mounting clamp onto transformer tank opening following recommended bolt torque. Excessive tightening force may crack the insulating body.
  • Install the protective cover over the shank‑type bushing connector after wiring completion, to prevent UV ageing, bird damage and outdoor contaminant accumulation.
  • Ensure the inner shank‑type connector is well‑aligned; avoid applying forced mechanical stress to the bushing insulator body.
  • After finishing installation, perform mandatory dielectric tests including power‑frequency withstand test and partial‑discharge measurement prior to transformer energization.

Routine Maintenance Guidance

  • Implement periodic visual inspection: examine insulator sheds for dirt deposits, surface cracks and chipping damage.
  • Check shank‑type bushing connector threaded terminals for signs of overheating; thermal imaging inspection is recommended for transformers under continuous load.
  • Carry out surface cleaning only when heavy contamination accumulates; use non‑abrasive compatible cleaning agents to avoid scratching the insulating surface.
  • Inspect protective‑cover condition regularly and replace damaged protective covers timely.
  • If cracks or insulation degradation are observed on insulator body, replace the whole bushing assembly immediately to avoid sudden transformer failure.

Conclusion

The 15‑34 kV /125 A ANSI Bushing (Shank‑type bushing connector) is a purpose‑built medium‑voltage insulating component for low‑current ANSI‑standard distribution transformers. Its compact shank‑through threaded‑connector structure delivers standardized mounting interface, adequate creepage performance for polluted outdoor environments, and stable 125 A current‑carrying capacity. Supported by matched aluminum clamp and protective‑cover accessories, this bushing fits pole‑mounted, pad‑mounted and industrial auxiliary transformers for utility, commercial and renewable‑energy projects.

Correct model selection, torque‑controlled standardized installation and simple preventive maintenance contribute to long‑term service life and reduce unplanned power‑grid interruptions. Within the North‑American power‑equipment market, ANSI shank‑type connector bushings remain a popular reliable solution for small‑capacity oil‑immersed distribution transformers.


Contact Us

Contact: Tianjin Delda Trading Co., Ltd

WhatsApp: +86 13662056855

Tel:

E-mail: solomon20210701@tjxddq.com

Add: Unit‑101, Workshop 3, Bozhong Automobile Industrial Park, No.5 Xianghui Road, Intersection of Xianghui Road and Gaoying Road, Beizhakou Town, Jinnan District, Tianjin, China