The 1KV/2000A DIN Bushing is a low‑voltage high‑current transformer insulating component manufactured in accordance with DIN 42531 installation dimensional standards and EN 60137 international insulator specifications. It belongs to the broad 1‑3KV /1000‑4500A DIN‑standard bushing product family, widely deployed on oil‑immersed distribution transformers, rectifier transformers and industrial power transformers for European, Southeast‑Asian, Middle‑East and African overseas projects adopting DIN‑IEC technical systems.
International transformer procurement engineers frequently search target keywords including 1KV/2000A DIN Bushing, DIN 1kV 2000A transformer bushing, low voltage high current DIN standard bushing for new‑build transformer BOM creation and spare‑part replacement sourcing. Different from medium‑voltage DIN bushings for 12kV‑52kV equipment, this 1 kV low‑voltage bushing focuses on ultra‑high continuous current transmission. The 2000 A rated current means this insulator handles heavy‑duty output‑side current for large‑capacity transformers, putting high requirements on conductor conductivity, heat dissipation performance and flange mechanical fastening strength.
Mounted on transformer tank wall openings, the 1KV/2000A DIN Bushing builds insulated electrical pathways for high‑current conductors passing between transformer internal windings and external low‑voltage busbar connection systems. Its standardized flange mounting design follows unified DIN dimension rules. For most standard DIN‑compliant transformer tanks, this bushing can be directly fitted without custom mechanical machining.
The 1KV/2000A DIN Bushing is a porcelain‑insulated low‑voltage transformer bushing with rated voltage 1 kV and rated continuous current 2000 Amperes. It is a solid‑terminal type bushing with multi‑hole flange layout for 2000A‑and‑above current grades. The main insulation body is anti‑pollution porcelain insulator, paired with high‑conductivity copper conductor assembly and corrosion‑resistant metal fittings.
As a high‑current member within the 1‑3 kV DIN bushing series, it covers scenarios far beyond ordinary 1000 A low‑voltage bushings. Its flange tank opening dimension follows DIN 42531 specification for ≥2000A current class, adopting 4‑M16 bolt fastening layout. Standard arcing distance is 57 mm and creepage distance reaches 70 mm, satisfying insulation requirements for most indoor and outdoor low‑voltage transformer operating environments.
Buyers must clearly distinguish this solid‑terminal DIN bushing from cable‑through‑type bushing. The 1KV/2000A DIN Bushing uses solid copper conductor and external flat connection terminals, not hollow cable‑penetration structure. These two types cannot be directly interchanged. Improper selection will trigger terminal mismatch, assembly failure and overheating risks under high‑current load. This bushing is heavily used for large‑capacity distribution transformers, industrial rectifier transformers and grid‑modernization projects applying European DIN standards.
Ultra‑High Continuous Current Carrying Capacity Optimized heavy‑duty copper conductor structure supports stable 2000 A long‑time continuous operation. It keeps low temperature rise under full‑load conditions and reduces local hot‑spot risks for heavy‑current transformer output sides.
DIN‑Standardized Flange Mounting Dimensions Strictly complies with DIN 42531 dimensional specifications for ≥2000A low‑voltage bushings. Standard 4‑M16 bolt hole layout enables drop‑in installation for most DIN‑standard transformer tanks, minimizing custom modification work during manufacturing or component replacement.
Stable Porcelain Insulation Performance High‑quality porcelain insulator delivers excellent anti‑aging, anti‑pollution and oil‑immersion resistance. It adapts to indoor substation rooms as well as outdoor pole‑mounted transformer working environments.
Excellent Compatibility with Transformer Mineral Oil Porcelain insulator and all metal accessories maintain stable chemical properties inside oil‑filled transformer housings. No swelling, decomposition or impurity contamination will appear after long‑term immersion in mineral transformer oil.
Compliance with International Testing Standards Designed according to EN 60137 insulator criteria. Qualified finished products pass power‑frequency withstand‑voltage test, partial‑discharge inspection and thermal cycle test, meeting market‑access requirements for most regions adopting IEC‑DIN power‑equipment standards.
Robust Terminal Connection Structure Large‑area flat spade terminal design provides sufficient contact surface for high‑current busbar connection. It lowers contact resistance during heavy‑current transmission and simplifies external bus‑bar assembly work.
| Parameter Item | 1KV/2000A DIN Bushing Specification |
|---|---|
| Rated Voltage | 1 kV |
| Rated Continuous Current | 2000 A |
| Applicable Standards | DIN |
| Insulator Material | Porcelain |
| Target Equipment | Oil‑immersed power & distribution transformer |
| Tank‑Opening Mounting Standard | DIN standard, 4‑M16 bolt layout for ≥2000A grade |
| Arcing Distance | 57 mm |
| Creepage Distance | 70 mm |
| Core Structure | Solid‑conductor flat spade terminal type |
| Typical Application | Large‑capacity 1kV side oil‑immersed transformers |
| Approximate Weight | 12 kg |
| Working Environment | Indoor / Outdoor, oil‑immersed inside transformer tank |
Tank‑Opening Dimension Confirmation Before installation, compare transformer tank opening drawing with DIN 42531 dimensions for 2000A class. Non‑standard hole positions cause bolt misalignment, which requires extra mechanical re‑processing of transformer tank walls.
Protection of Sealing Surfaces Avoid scratches, burrs and foreign debris on flange gasket contact faces during handling and installation. Damaged sealing surfaces will cause transformer‑oil leakage after tightening. Install qualified oil‑resistant rubber gaskets between bushing flange and transformer tank wall.
Strict Terminal Torque Control Under 2000 A heavy‑current operating conditions, follow recommended torque values when fastening external bus‑bar terminals. Insufficient torque creates excessive contact resistance and serious over‑heating; over‑tightening may crack porcelain sheds or damage threaded metal parts.
Prevent Mechanical Impact Damage Porcelain insulator is brittle. Avoid heavy knocking, extrusion or bending stress in transportation and installation. Invisible internal cracks induced by mechanical shock may lead to insulation breakdown after equipment energization.
Pre‑commissioning Electrical Inspection After completing full assembly, carry out power‑frequency withstand‑voltage test and partial‑discharge test following EN 60137 requirements. Double‑check all sealing points to eliminate oil‑leak hazards before putting the transformer into service.
‑ Large‑capacity oil‑immersed distribution transformers complying with DIN‑IEC standards ‑ Industrial rectifier transformers and heavy‑duty power‑supply transformers ‑ Box‑type substation transformers for European, Southeast‑Asian, Middle‑East and African power‑grid construction ‑ Spare‑part maintenance and retrofit projects for existing DIN‑system large‑capacity transformers ‑ Renewable‑energy supporting transformers with high‑current low‑voltage output terminals
While sourcing 1KV/2000A DIN Bushing, buyers should not merely check rated voltage 1 kV and rated current 2000 A. Multiple key parameters need cross‑verification. First, confirm it is solid flat‑spade terminal‑type bushing instead of hollow cable‑through bushing, as these two structures cannot substitute for each other.
Second, validate that the flange hole pattern matches DIN 42531 specifications for 2000A‑and‑above current class. For coastal or heavily‑polluted industrial zones, evaluate whether extended creepage‑distance variants are required for local grid anti‑pollution regulations. Request formal dielectric‑test reports and material certificates from suppliers.
Never fit DIN‑standard bushings onto ANSI‑standard transformer tanks. ANSI and DIN systems adopt totally different flange benchmarks, terminal forms and installation dimensions, which will trigger assembly barriers and potential safety risks. When actual operating current exceeds 2000 A, select higher‑current models from the 1‑3KV /1000‑4500A DIN bushing product portfolio.
The 1KV/2000A DIN Bushing is a vital low‑voltage high‑current insulating component for large‑capacity DIN‑standard transformers. It combines heavy‑current carrying capability, standardized DIN mounting and reliable porcelain insulation performance. For global transformer manufacturers and maintenance contractors serving DIN‑spec markets, correct specification of this bushing improves transformer assembly efficiency and long‑term operational safety.
Recognizing its structural differences from cable‑through‑type and ANSI‑standard bushings helps international power‑component purchasers avoid specification errors during procurement, cutting project rework costs and potential equipment‑failure risks.