DIN Bushing

  • DIN Transformer Bushing Full Range: 5 Series, 42 Models Covering 1~52kV and 250~4500A
DIN Transformer Bushing Full Range: 5 Series, 42 Models Covering 1~52kV and 250~4500A

DIN Transformer Bushing Full Range: 5 Series, 42 Models Covering 1~52kV and 250~4500A

Product Overview

This page summarizes Xingda's full range of transformer bushings manufactured to the DIN (German) standard system — five series, 42 standard models covering 1~52kV and 250~4500A. All are brown-glazed porcelain with single or multiple sheds, supplied complete with 10×10 square-steel mounting and tank-cover opening fittings.

Model designation is straightforward: DIN – voltage / current — e.g. DIN-24/2000 is the 24kV / 2000A bushing. Suffix rules: the three reinforced-creepage 36kV variants are marked .A / .B / .C; threaded-connection types carry the suffix .1; internal codes follow XD.current.voltage.DIN. Voltage, current and construction type — three parameters fix the model.

The five series fall into three construction groups: ① LV outlet bushings (1~3kV in 250~630A and 1000~4500A steps); ② cable-through bushings (12~36kV, 250~630A, cable passing through the central tube); ③ threaded-connection and high-current MV bushings (12~36kV 250~630A threaded type, and 12~52kV 1000~3150A high-current type).

Models & Specifications

Table 1 | 1~3kV LV outlet bushings (250~630A, single shed, 10×10 square-steel mounting)

CodeModelHh2h3Mdd1d2d3Opening d0Arcing h1CreepageShedsWeight(kg)
XD.0250.1.DINDIN-1/25020562.528.5M12×1.7550605028495511
XD.0400.1.DINDIN-1/4002607843M16×2.070857045597011.6
XD.0630.1.DINDIN-1/6302607843M20×2.570857045597012.4
XD.0250.3.DINDIN-3/25027287.528.5M12×1.75757060398912011.5
XD.0400.3.DINDIN-3/40031810343M16×2.0908570398912011.9
XD.0630.3.DINDIN-3/63031810343M20×2.5908570458912012.9

Table 2 | 1~3kV high-current LV bushings (1000~4500A, single shed, flat terminal pads)

CodeModelHh2h3h4a3×a4a1×a2Φd4tMdd1d2d3SS1Opening d0Arcing h1CreepageWeight(kg)
XD.1000.1.DINDIN-1/100032458174~860×6026×26Φ1410M30×2901109070505657755.5
XD.2000.1.DINDIN-1/200040563226~10100×10050×40Φ1415M42×31041251051006070587012
XD.3150.1.DINDIN-1/315043468276~10120×12060×40Φ1415M48×31251501251106090577516.5
XD.1000.3.DINDIN-3/100037278174~860×6026×26Φ1410M30×211011090705056871206.5
XD.2000.3.DINDIN-3/200045083226~10110×10050×40Φ1415M42×312512510510060708912013.5
XD.3150.3.DINDIN-3/315049588276~10120×12060×40Φ1415M48×314515012511060908812018.7
XD.4500.3.DINDIN-3/4500560101306~12150×15070×70Φ1820M50×3175160—1601001199512533.5

※ 1000A terminal: 2-Φ4 holes; 2000A and above: 4-Φ4 holes. Terminal-pad sizes a3×a4 / a1×a2 as per catalog drawing. d3 of DIN-3/4500 is blank in the original catalog.

Table 3 | 12~36kV cable-through bushings (250~630A, cable passing through the central tube)

CodeModelHh2h3Mdd1d2d3d4ECOpening d0Arcing h1CreepageShedsWeight(kg)
XD.0250.12.DINDIN-12/25037125459M12×1.7514087450150857817530025
XD.0630.12.DINDIN-12/63040325499M20×2.5150128860180859217531027.1
XD.0250.24.DINDIN-24/25046134474M12×1.75145874501501557825044036.6
XD.0630.24.DINDIN-24/63049334474M20×2.51601288601801559225046039.3
XD.0250.36.DINDIN-36/25056144474M12×1.75155874501502207835061047.6
XD.0630.36.DINDIN-36/63061846990M20×2.518012886020022092355670412
XD.0250.36.A.DINDIN-36/25056944474M12×1.75170874501502207835099689.5
XD.0250.36.B.DINDIN-36/25069147674M12×1.7517587450150220783821116912
XD.0250.36.C.DINDIN-36/250711540140M16×2.019087470150200783921207815
XD.0400.36.C.DINDIN-36/400711540140M16×2.01906.57470150200783921207815
XD.0630.36.C.DINDIN-36/630711540140M20×2.5190127470150200783921207815

※ Φd2 = tail anchor-thread diameter. Cover flanges: d0=78 with Φ122 flange / 4-M10 (Φ58 PCD); d0=92 with Φ160 flange / 4-M16 (Φ90 PCD). .A/.B/.C are three reinforced-creepage shed options for 36kV (996 / 1116 / 1207 mm).

Table 4 | 12~36kV threaded-connection bushings (250~630A, suffix .1)

CodeModelHh2h3Mdd1d3d4ECOpening d0Arcing h1CreepageShedsWeight(kg)
XD.0250.12.1.DINDIN-12/25043111960M12×1.751407451146857817530025.3
XD.0630.12.1.DINDIN-12/63047813475M20×2.51508860180859217531028
XD.0250.24.1.DINDIN-24/25052113460M12×1.7514574511461557825044037.2
XD.0630.24.1.DINDIN-24/63056814975M20×2.5160886018015592250460310.4
XD.0250.36.1.DINDIN-36/25062113460M12×1.7515574511462207835061048.3
XD.0630.36.1.DINDIN-36/63069316575M20×2.5180886020022092355670413.5

Table 5 | 12~52kV high-current bushings (1000~3150A, 2~6 sheds, creepage up to 950 mm)

CodeModelHh2h3Mdd1d3d4tECOpening d0Arcing h1CreepageShedsWeight(kg)
XD.1000.12.DINDIN-12/100063717585M30×2.01701081001022585115166340218
XD.2000.12.DINDIN-12/2000737205115M42×3.01701311201523585135166350223
XD.3150.12.DINDIN-12/3150772215125M48×3.01701311201523585135166350229
XD.1000.24.DINDIN-24/100072218585M30×2.018510810010225155115241500318
XD.2000.24.DINDIN-24/2000822215115M42×3.021013112015235155135241500329
XD.3150.24.DINDIN-24/3150857225125M48×3.021013112015235155135241500333
XD.1000.36.DINDIN-36/100085221085M30×2.017510810010225220115346640422
XD.2000.36.DINDIN-36/2000952240115M42×3.023013112015235220135346750435
XD.3150.36.DINDIN-36/3150987250125M48×3.023013112015235220135346750440
XD.1000.52.DINDIN-52/10001012280100M30×2.025013112010——135432950636
XD.2000.52.DINDIN-52/20001112310130M42×3.025013112015——135432950645
XD.3150.52.DINDIN-52/31501147320140M48×3.025013112015——135432950650

※ DIN-12/1000: cover opening d0=115 (Φ180 flange, 6-M12); all other steps d0=135 (Φ200 flange, 8-M12, Φ70 PCD). Columns E and C are blank for the 52kV models in the original catalog.

Mounting & Fittings

LV series (Tables 1–2) is located in the tank-cover opening by a 10×10 square steel bar: openings of Φd0 = 28~45 mm for small-current steps and 56~119 mm for high-current steps. High-current models use flat terminal pads (2-Φ4 holes for 1000A, 4-Φ4 for 2000A and above), pad sizes from 60×60 up to 150×150, with threads rising from M30×2 to M50×3 with the current rating.

Cable-through bushings (Table 3): the cable passes through the central tube and the outdoor terminal leads off to the side. Threaded-connection types (Table 4, suffix .1) clamp the lead directly by the top thread. High-current MV bushings (Table 5) use two cover openings Φ115 / Φ135 with flanges Φ180 / Φ200, fixed by 6-M12 or 8-M12 bolts (Φ70 PCD).

Typical Applications

ApplicationRecommended SeriesNotes
LV outlet of European-standard distribution transformersDIN-1/x / DIN-3/x (250~630A)Compact single-shed design, 1~3 kg, arcing distance 49~89 mm
High-current LV outlet (1~4.5kA)DIN-1/1000~3150 / DIN-3/1000~4500Terminal pads up to 150×150, M50×3 thread
HV inlet of 12~36kV distribution transformers (cable-through)DIN-12/24/36-250~630Cable passes through the centre, creepage 300~670 mm
Reinforced 36kV for polluted / humid areasDIN-36/250 .A/.B/.CCreepage reinforced to 996 / 1116 / 1207 mm
Pad-mounted and substation transformers, high-current MVDIN-12~52/1000~31502~6 sheds, creepage up to 950 mm, M30~M48 terminals

Why Xingda

The DIN series is fully manufactured by Tianjin Xingda. Tooling for all five series and 42 standard models is in place and supply is stable; listed dimensions refer to standard products, and non-standard sheds, extended heights and special openings can be customized to customer drawings. The same factory supplies DIN, ANSI, NBR Brazilian and GB bushing lines, so a transformer manufacturer can equip both export and domestic units from a single purchase. Every bushing is delivered with sealing and mounting fittings, ready to assemble on the tank cover.


Contact Us

Contact: Tianjin Juyida Technology Co., Ltd

WhatsApp: +86 13662056855

Tel:

E-mail: solomon20210701@tjxddq.com

Add: Unit‑101, Workshop 3, Bozhong Automobile Industrial Park, No.5 Xianghui Road, Intersection of Xianghui Road and Gaoying Road, Beizhakou Town, Jinnan District, Tianjin, China