  • Transformer Tank Instrument Duo: YZ-70 Pressure Vacuum Gauge + BWS-70 Thermometer, Full Range -0.08~0.08 MPa / -10~130°C
Transformer Tank Instrument Duo: YZ-70 Pressure Vacuum Gauge + BWS-70 Thermometer, Full Range -0.08~0.08 MPa / -10~130°C

Transformer Tank Instrument Duo: YZ-70 Pressure Vacuum Gauge + BWS-70 Thermometer, Full Range -0.08~0.08 MPa / -10~130°C

Product Overview

This page presents two Tianjin Xingda monitoring instruments for oil-immersed transformer tanks: the YZ-70 Pressure Vacuum Gauge and the BWS-70 Thermometer (oil temperature indicator). Both instruments are purpose-designed for box-type transformers, share a unified M27×2 mounting thread and a Φ33 tank cover opening, with the base welded by the transformer manufacturer (user provided base). Installation and maintenance are simple, making them the fundamental instruments for on-line monitoring of transformer operating status.

The YZ-70 Pressure Vacuum Gauge is a pressure measuring instrument specially designed for box-type power transformers. It directly reflects the internal pressure changes caused by changes in the oil temperature, allowing operators to observe the operating status of the transformer at any time. Measuring range is -0.08~0.08 MPa (customizable according to user requirements), with Class 1.6 accuracy.

The BWS-70 Thermometer is a temperature indicator installed on the side wall of the transformer. It features sensitive response, clear indication, simple structure and good reliability. The instrument casing is made of stainless steel for a beautiful appearance and long service life. Temperature measuring range is -10°C~130°C with Class 2.5 accuracy, and the bulb withstands up to 1.6 MPa.

Model designation: YZ-70 pressure vacuum gauge, BWS-70 thermometer. All mounting dimensions are listed below as standard data; non-standard requirements can be manufactured to customer drawings.

Product Features

  • Purpose-built: designed for box-type power transformer duty — directly reflects internal pressure changes caused by oil temperature variation, enabling operating-status judgment without opening the tank;
  • Reliable accuracy: Class 1.6 (YZ-70) and Class 2.5 (BWS-70), factory-calibrated with clear, easy-to-read dials;
  • Wide environmental range: both instruments operate long-term at -35°C~80°C and humidity ≤85%, covering all outdoor transformer conditions;
  • Unified interface: M27×2 mounting thread and Φ33 tank cover opening for both — the base is provided and welded by the transformer manufacturer per the dimension table;
  • Customizable range: YZ-70 pressure range customizable per user requirements; BWS-70 bulb withstands 1.6 MPa with matched insertion depth;
  • Easy maintenance: if the YZ-70 pointer drifts off zero, open the transparent cover and gently rotate the zero-adjustment screw on the right side; the BWS-70 stainless steel casing is rust-proof and durable.

Technical Parameters and Mounting Dimensions

Table 1 | YZ-70 Pressure Vacuum Gauge — Main Parameters

ItemParameter
Measuring range-0.08~0.08 MPa (customizable according to user requirements)
Accuracy classClass 1.6
Ambient temperature-35°C~80°C
Ambient humidity≤85%
Installation connectorM27×2
Case diameter ΦD72
Gauge head height36 (thread 17 + 5, connector Φ22)
Matching base (user provided)Φ40, height 22, hole Φ7
Tank cover openingΦ33

Table 2 | BWS-70 Thermometer — Main Parameters

ItemParameter
Temperature measuring range-10°C~130°C
Indication accuracyClass 2.5
Ambient temperature-35°C~80°C
Bulb withstanding pressure1.6 MPa
Installation connectorM27×2
Case diameter ΦD72, head height 21
Bulb stem total length150 (thread 17 + 4, Φ24 stem, Φ6 bulb tip)
Matching base (user provided)Φ60, height 25/22, hole Φ10
Tank cover openingΦ33

※ To ensure measuring accuracy, the bulb shall be inserted into the measured medium at a length greater than 100 mm; insertion depth can be matched to the oil conservator / tank on request.

Usage and Maintenance

  • YZ-70: ① Install the instrument vertically to ensure indication accuracy; ② Keep the measured value within 3/4 of the upper limit; ③ Tighten the installation joint first, then straighten the instrument — do not use the instrument housing as a wrench to adjust the angle; ④ Handle with care during installation and transport and avoid significant vibration, which may displace internal mechanisms and cause misalignment; ⑤ Under normal use, calibrate every 6 months; ⑥ If the pointer is offset from the zero line, open the transparent cover and gently rotate the zero-adjustment screw on the right side to reset it.
  • BWS-70: ① Insert the bulb into the measured medium at a length greater than 100 mm to ensure temperature-measuring accuracy; ② Avoid collision, bending and deformation of the bulb during use, installation and transportation; ③ Straighten the instrument and tighten the installation joint during installation — do not use the casing as a wrench; ④ Under normal use, calibrate every 12 months.

Typical Applications

ApplicationRecommended InstrumentNotes
Oil pressure monitoring for pad-mounted / box-type transformersYZ-70 pressure vacuum gaugeFull -0.08~0.08 MPa range, Class 1.6, intuitive abnormal-pressure judgment
Oil temperature monitoring for distribution transformersBWS-70 thermometer-10~130°C, Class 2.5, stainless steel case, side-wall direct reading
Outdoor high-humidity, condensation-prone sitesBothReliable long-term at -35~80°C and humidity ≤85%
Factory complete outfittingGauge + thermometer pairUnified M27×2 thread, Φ33 opening both — base welded once

Why Xingda

The YZ-70 pressure vacuum gauge and BWS-70 thermometer are members of Tianjin Xingda's transformer accessory family, with ranges, accuracy classes and insertion depths all customizable to customer requirements. Together with bushings (GB / ANSI / NBR / DIN / EN / flanged / epoxy resin), moisture absorbers, non-excitation tap changers, pressure relief valves, oil level gauges and oil drain valves produced in the same factory, Xingda supplies the complete transformer package — bushings, oil protection and monitoring instruments in one purchase, with interface and opening dimensions matching the tables for direct assembly and shorter production cycles.


Contact Us

Contact: Tianjin Juyida Technology Co., Ltd

WhatsApp: +86 13662056855

Tel:

E-mail: solomon20210701@tjxddq.com

Add: Unit‑101, Workshop 3, Bozhong Automobile Industrial Park, No.5 Xianghui Road, Intersection of Xianghui Road and Gaoying Road, Beizhakou Town, Jinnan District, Tianjin, China